# Protocol Mapping Configuration UI Design
|
|||
|
|
|
|||
|
|
## Overview
|
|||
|
|
This document outlines the comprehensive UI design for configuring database-to-protocol mappings through the dashboard interface, supporting Modbus, OPC UA, and other industrial protocols.
|
|||
|
|
|
|||
|
|
## 🎯 Design Goals
|
|||
|
|
- **Intuitive**: Easy for both technical and non-technical users
|
|||
|
|
- **Visual**: Clear representation of database-to-protocol data flow
|
|||
|
|
- **Configurable**: Flexible mapping configuration without code changes
|
|||
|
|
- **Validated**: Real-time conflict detection and validation
|
|||
|
|
- **Scalable**: Support for multiple stations, pumps, and protocols
|
|||
|
|
- **Protocol-Agnostic**: Unified interface for Modbus, OPC UA, and other protocols
|
|||
|
|
|
|||
|
|
## 🏗️ Architecture
|
|||
|
|
|
|||
|
|
### Data Flow
|
|||
|
|
```
|
|||
|
|
Database Sources → Mapping Configuration → Protocol Endpoints
|
|||
|
|
↓ ↓ ↓
|
|||
|
|
pump_plans.speed_hz → Setpoint mapping → Modbus: Holding register 40001
|
|||
|
|
pumps.status_code → Status mapping → OPC UA: ns=2;s=Station.Pump.Status
|
|||
|
|
safety.flags → Safety mapping → Modbus: Coil register 0
|
|||
|
|
flow_meters.rate → Flow mapping → OPC UA: ns=2;s=Station.Flow.Rate
|
|||
|
|
```
|
|||
|
|
|
|||
|
|
### Component Structure
|
|||
|
|
```javascript
|
|||
|
|
<ProtocolMappingDashboard>
|
|||
|
|
<ProtocolSelector />
|
|||
|
|
<StationSelector />
|
|||
|
|
<PumpSelector />
|
|||
|
|
<MappingGrid />
|
|||
|
|
<MappingConfigurationModal />
|
|||
|
|
<RealTimePreview />
|
|||
|
|
<ValidationPanel />
|
|||
|
|
<TemplateGallery />
|
|||
|
|
<BulkOperations />
|
|||
|
|
</ProtocolMappingDashboard>
|
|||
|
|
```
|
|||
|
|
|
|||
|
|
## 📋 UI Components
|
|||
|
|
|
|||
|
|
### 1. Main Dashboard Layout
|
|||
|
|
```
|
|||
|
|
┌─────────────────────────────────────────────────────────────────┐
|
|||
|
|
│ PROTOCOL MAPPING CONFIGURATION │
|
|||
|
|
├─────────────────────────────────────────────────────────────────┤
|
|||
|
|
│ [Protocols] [Stations] [Pumps] [Mapping View] [Templates] │
|
|||
|
|
└─────────────────────────────────────────────────────────────────┘
|
|||
|
|
```
|
|||
|
|
|
|||
|
|
### 2. Visual Protocol Mapping View
|
|||
|
|
|
|||
|
|
#### **Layout**:
|
|||
|
|
```
|
|||
|
|
┌─────────────────┐ ┌─────────────────────────────────────────────┐
|
|||
|
|
│ │ │ PROTOCOL MAPPING │
|
|||
|
|
│ PUMP LIST │ │ ┌───┬─────────────┬─────────────┬─────────┐ │
|
|||
|
|
│ │ │ │ # │ DATA TYPE │ DB SOURCE │ ADDRESS │ │
|
|||
|
|
│ STATION_001 │ │ ├───┼─────────────┼─────────────┼─────────┤ │
|
|||
|
|
│ ├─ PUMP_001 │ │ │ 0 │ Setpoint │ speed_hz │ 40001 │ │
|
|||
|
|
│ ├─ PUMP_002 │ │ │ 1 │ Status │ status_code │ 40002 │ │
|
|||
|
|
│ ├─ PUMP_003 │ │ │ 2 │ Power │ power_kw │ 40003 │ │
|
|||
|
|
│ │ │ │ 3 │ Level │ level_m │ 40004 │ │
|
|||
|
|
│ STATION_002 │ │ │ 4 │ Flow │ flow_m3h │ 40005 │ │
|
|||
|
|
│ ├─ PUMP_004 │ │ │ 5 │ Safety │ safety_flag │ 40006 │ │
|
|||
|
|
│ │ │ └───┴─────────────┴─────────────┴─────────┘ │
|
|||
|
|
└─────────────────┘ └─────────────────────────────────────────────┘
|
|||
|
|
```
|
|||
|
|
|
|||
|
|
### 3. Multi-Protocol Configuration Form
|
|||
|
|
|
|||
|
|
#### **Modal/Form Layout**:
|
|||
|
|
```
|
|||
|
|
┌─────────────────────────────────────────────────────────────────┐
|
|||
|
|
│ CONFIGURE PROTOCOL MAPPING │
|
|||
|
|
├─────────────────────────────────────────────────────────────────┤
|
|||
|
|
│ Protocol: [Modbus TCP ▼] [OPC UA ▼] [Custom Protocol] │
|
|||
|
|
│ │
|
|||
|
|
│ Station: [STATION_001 ▼] Pump: [PUMP_001 ▼] │
|
|||
|
|
│ │
|
|||
|
|
│ Data Type: [Setpoint ▼] Protocol Address: │
|
|||
|
|
│ │
|
|||
|
|
│ MODBUS: [40001] (Holding Register) │
|
|||
|
|
│ OPC UA: [ns=2;s=Station.Pump.Setpoint] │
|
|||
|
|
│ │
|
|||
|
|
│ Database Source: │
|
|||
|
|
│ [●] pump_plans.suggested_speed_hz │
|
|||
|
|
│ [ ] pumps.default_setpoint_hz │
|
|||
|
|
│ [ ] Custom SQL: [___________________________] │
|
|||
|
|
│ │
|
|||
|
|
│ Data Transformation: │
|
|||
|
|
│ [●] Direct value [ ] Scale: [×10] [÷10] │
|
|||
|
|
│ [ ] Offset: [+___] [ ] Clamp: [min___] [max___] │
|
|||
|
|
│ │
|
|||
|
|
│ Validation: ✅ No conflicts detected │
|
|||
|
|
│ │
|
|||
|
|
│ [SAVE MAPPING] [TEST MAPPING] [CANCEL] │
|
|||
|
|
└─────────────────────────────────────────────────────────────────┘
|
|||
|
|
```
|
|||
|
|
|
|||
|
|
### 4. Protocol-Specific Address Configuration
|
|||
|
|
|
|||
|
|
#### **Modbus Configuration**:
|
|||
|
|
```
|
|||
|
|
┌─────────────────────────────────────────────────────────────────┐
|
|||
|
|
│ MODBUS ADDRESS CONFIGURATION │
|
|||
|
|
├─────────────────────────────────────────────────────────────────┤
|
|||
|
|
│ Register Type: [● Holding ○ Input ○ Coil ○ Discrete] │
|
|||
|
|
│ │
|
|||
|
|
│ Address: [40001] │
|
|||
|
|
│ Size: [1 register] │
|
|||
|
|
│ Data Type: [16-bit integer] │
|
|||
|
|
│ │
|
|||
|
|
│ Byte Order: [Big Endian] [Little Endian] │
|
|||
|
|
│ Word Order: [High Word First] [Low Word First] │
|
|||
|
|
└─────────────────────────────────────────────────────────────────┘
|
|||
|
|
```
|
|||
|
|
|
|||
|
|
#### **OPC UA Configuration**:
|
|||
|
|
```
|
|||
|
|
┌─────────────────────────────────────────────────────────────────┐
|
|||
|
|
│ OPC UA NODE CONFIGURATION │
|
|||
|
|
├─────────────────────────────────────────────────────────────────┤
|
|||
|
|
│ Node ID: [ns=2;s=Station.Pump.Setpoint] │
|
|||
|
|
│ │
|
|||
|
|
│ Namespace: [2] │
|
|||
|
|
│ Browse Name: [Setpoint] │
|
|||
|
|
│ Display Name: [Pump Setpoint] │
|
|||
|
|
│ │
|
|||
|
|
│ Data Type: [Double] [Float] [Int32] [Int16] [Boolean] │
|
|||
|
|
│ Access Level: [CurrentRead] [CurrentWrite] [HistoryRead] │
|
|||
|
|
└─────────────────────────────────────────────────────────────────┘
|
|||
|
|
```
|
|||
|
|
|
|||
|
|
### 5. Drag & Drop Interface
|
|||
|
|
|
|||
|
|
#### **Visual Design**:
|
|||
|
|
```
|
|||
|
|
┌─────────────────┐ ┌─────────────────┐ ┌─────────────────┐
|
|||
|
|
│ DATABASE │ │ MAPPING │ │ PROTOCOL │
|
|||
|
|
│ SOURCES │ │ WORKSPACE │ │ ENDPOINTS │
|
|||
|
|
│ │ │ │ │ │
|
|||
|
|
│ ┌─────────────┐ │ │ ┌─────────────┐ │ │ ┌─────────────┐ │
|
|||
|
|
│ │ pump_plans │ │ │ │ Setpoint │ │ │ │ Modbus │ │
|
|||
|
|
│ │ speed_hz │──────▶│ speed_hz │──────▶│ 40001 │ │
|
|||
|
|
│ └─────────────┘ │ │ └─────────────┘ │ │ └─────────────┘ │
|
|||
|
|
│ │ │ │ │ │
|
|||
|
|
│ ┌─────────────┐ │ │ ┌─────────────┐ │ │ ┌─────────────┐ │
|
|||
|
|
│ │ pumps │ │ │ │ Status │ │ │ │ OPC UA │ │
|
|||
|
|
│ │ status │──────▶│ status_code │──────▶│ ns=2;s=... │ │
|
|||
|
|
│ └─────────────┘ │ │ └─────────────┘ │ │ └─────────────┘ │
|
|||
|
|
│ │ │ │ │ │
|
|||
|
|
│ ┌─────────────┐ │ │ ┌─────────────┐ │ │ ┌─────────────┐ │
|
|||
|
|
│ │ safety │ │ │ │ Safety │ │ │ │ Modbus │ │
|
|||
|
|
│ │ flags │──────▶│ safety_flag │──────▶│ Coil 0 │ │
|
|||
|
|
│ └─────────────┘ │ │ └─────────────┘ │ │ └─────────────┘ │
|
|||
|
|
└─────────────────┘ └─────────────────┘ └─────────────────┘
|
|||
|
|
```
|
|||
|
|
|
|||
|
|
### 6. Real-time Preview Panel
|
|||
|
|
|
|||
|
|
#### **Layout**:
|
|||
|
|
```
|
|||
|
|
┌─────────────────────────────────────────────────────────────────┐
|
|||
|
|
│ REAL-TIME PREVIEW │
|
|||
|
|
├─────────────────┬─────────────┬─────────────┬───────────────────┤
|
|||
|
|
│ Database Value │ Transform │ Protocol │ Current Value │
|
|||
|
|
├─────────────────┼─────────────┼─────────────┼───────────────────┤
|
|||
|
|
│ 42.3 Hz │ ×10 → │ Modbus 40001│ 423 │
|
|||
|
|
│ Running │ Direct │ OPC UA Node │ 1 │
|
|||
|
|
│ 15.2 kW │ Direct │ Modbus 40003│ 15 │
|
|||
|
|
│ 2.1 m │ ×100 → │ OPC UA Node │ 210 │
|
|||
|
|
└─────────────────┴─────────────┴─────────────┴───────────────────┘
|
|||
|
|
```
|
|||
|
|
|
|||
|
|
### 7. Protocol-Specific Templates
|
|||
|
|
|
|||
|
|
#### **Template Gallery**:
|
|||
|
|
```
|
|||
|
|
┌─────────────────────────────────────────────────────────────────┐
|
|||
|
|
│ PROTOCOL TEMPLATES │
|
|||
|
|
├─────────────────┬─────────────────┬─────────────────────────────┤
|
|||
|
|
│ Modbus Standard │ OPC UA Standard │ Custom Template │
|
|||
|
|
│ │ │ │
|
|||
|
|
│ • Holding Regs │ • Analog Items │ • Import from file │
|
|||
|
|
│ • Input Regs │ • Digital Items │ • Export current │
|
|||
|
|
│ • Coils │ • Complex Types │ • Save as template │
|
|||
|
|
│ • Discrete │ • Methods │ │
|
|||
|
|
│ │ │ │
|
|||
|
|
│ [APPLY] │ [APPLY] │ [CREATE] │
|
|||
|
|
└─────────────────┴─────────────────┴─────────────────────────────┘
|
|||
|
|
```
|
|||
|
|
|
|||
|
|
## 🔧 Technical Implementation
|
|||
|
|
|
|||
|
|
### Data Models
|
|||
|
|
```typescript
|
|||
|
|
interface ProtocolMapping {
|
|||
|
|
id: string;
|
|||
|
|
protocolType: 'modbus_tcp' | 'opcua' | 'custom';
|
|||
|
|
stationId: string;
|
|||
|
|
pumpId: string;
|
|||
|
|
dataType: 'setpoint' | 'status' | 'power' | 'flow' | 'level' | 'safety';
|
|||
|
|
protocolAddress: string; // Register address or OPC UA node
|
|||
|
|
dbSource: string;
|
|||
|
|
transformation: TransformationRule[];
|
|||
|
|
|
|||
|
|
// Protocol-specific properties
|
|||
|
|
modbusConfig?: {
|
|||
|
|
registerType: 'holding' | 'input' | 'coil' | 'discrete';
|
|||
|
|
size: number;
|
|||
|
|
dataType: 'int16' | 'int32' | 'float' | 'boolean';
|
|||
|
|
byteOrder: 'big_endian' | 'little_endian';
|
|||
|
|
};
|
|||
|
|
|
|||
|
|
opcuaConfig?: {
|
|||
|
|
namespace: number;
|
|||
|
|
browseName: string;
|
|||
|
|
displayName: string;
|
|||
|
|
dataType: string;
|
|||
|
|
accessLevel: string[];
|
|||
|
|
};
|
|||
|
|
}
|
|||
|
|
|
|||
|
|
interface TransformationRule {
|
|||
|
|
type: 'scale' | 'offset' | 'clamp' | 'round';
|
|||
|
|
parameters: any;
|
|||
|
|
}
|
|||
|
|
```
|
|||
|
|
|
|||
|
|
### API Endpoints
|
|||
|
|
```
|
|||
|
|
GET /api/v1/dashboard/protocol-mappings
|
|||
|
|
POST /api/v1/dashboard/protocol-mappings
|
|||
|
|
PUT /api/v1/dashboard/protocol-mappings/{id}
|
|||
|
|
DELETE /api/v1/dashboard/protocol-mappings/{id}
|
|||
|
|
POST /api/v1/dashboard/protocol-mappings/validate
|
|||
|
|
POST /api/v1/dashboard/protocol-mappings/test
|
|||
|
|
GET /api/v1/dashboard/protocol-mappings/templates
|
|||
|
|
POST /api/v1/dashboard/protocol-mappings/import
|
|||
|
|
GET /api/v1/dashboard/protocol-mappings/export
|
|||
|
|
|
|||
|
|
# Protocol-specific endpoints
|
|||
|
|
GET /api/v1/dashboard/protocol-mappings/modbus
|
|||
|
|
GET /api/v1/dashboard/protocol-mappings/opcua
|
|||
|
|
POST /api/v1/dashboard/protocol-mappings/modbus/discover
|
|||
|
|
POST /api/v1/dashboard/protocol-mappings/opcua/browse
|
|||
|
|
```
|
|||
|
|
|
|||
|
|
### Integration Points
|
|||
|
|
|
|||
|
|
#### 1. Configuration Manager Integration
|
|||
|
|
```python
|
|||
|
|
class ConfigurationManager:
|
|||
|
|
def __init__(self):
|
|||
|
|
self.protocol_mappings: List[ProtocolMapping] = []
|
|||
|
|
|
|||
|
|
def add_protocol_mapping(self, mapping: ProtocolMapping) -> bool:
|
|||
|
|
# Validate and add mapping
|
|||
|
|
pass
|
|||
|
|
|
|||
|
|
def get_protocol_mappings(self,
|
|||
|
|
protocol_type: str = None,
|
|||
|
|
station_id: str = None,
|
|||
|
|
pump_id: str = None) -> List[ProtocolMapping]:
|
|||
|
|
# Filter mappings by protocol/station/pump
|
|||
|
|
pass
|
|||
|
|
```
|
|||
|
|
|
|||
|
|
#### 2. Protocol Server Integration
|
|||
|
|
```python
|
|||
|
|
# Modbus Server Integration
|
|||
|
|
class ModbusServer:
|
|||
|
|
def __init__(self, configuration_manager: ConfigurationManager):
|
|||
|
|
self.configuration_manager = configuration_manager
|
|||
|
|
|
|||
|
|
async def _update_registers(self):
|
|||
|
|
modbus_mappings = self.configuration_manager.get_protocol_mappings('modbus_tcp')
|
|||
|
|
for mapping in modbus_mappings:
|
|||
|
|
value = self._get_database_value(mapping.dbSource)
|
|||
|
|
transformed_value = self._apply_transformations(value, mapping.transformation)
|
|||
|
|
self._write_register(mapping.protocolAddress, transformed_value, mapping.modbusConfig.registerType)
|
|||
|
|
|
|||
|
|
# OPC UA Server Integration
|
|||
|
|
class OPCUAServer:
|
|||
|
|
def __init__(self, configuration_manager: ConfigurationManager):
|
|||
|
|
self.configuration_manager = configuration_manager
|
|||
|
|
|
|||
|
|
async def update_nodes(self):
|
|||
|
|
opcua_mappings = self.configuration_manager.get_protocol_mappings('opcua')
|
|||
|
|
for mapping in opcua_mappings:
|
|||
|
|
value = self._get_database_value(mapping.dbSource)
|
|||
|
|
transformed_value = self._apply_transformations(value, mapping.transformation)
|
|||
|
|
await self._write_node(mapping.protocolAddress, transformed_value)
|
|||
|
|
```
|
|||
|
|
|
|||
|
|
## 🎨 Visual Design System
|
|||
|
|
|
|||
|
|
### Color Scheme by Protocol
|
|||
|
|
- **Modbus**: Blue (#2563eb)
|
|||
|
|
- **OPC UA**: Green (#16a34a)
|
|||
|
|
- **Custom Protocols**: Purple (#9333ea)
|
|||
|
|
- **Success**: Green (#16a34a)
|
|||
|
|
- **Warning**: Yellow (#d97706)
|
|||
|
|
- **Error**: Red (#dc2626)
|
|||
|
|
|
|||
|
|
### Icons
|
|||
|
|
- 🔌 Modbus
|
|||
|
|
- 🌐 OPC UA
|
|||
|
|
- ⚙️ Custom Protocol
|
|||
|
|
- ✅ Valid mapping
|
|||
|
|
- ⚠️ Warning
|
|||
|
|
- ❌ Error
|
|||
|
|
- 🔄 Active/live data
|
|||
|
|
- 📊 Data preview
|
|||
|
|
|
|||
|
|
## 🔍 Validation Rules
|
|||
|
|
|
|||
|
|
### Protocol-Specific Validation
|
|||
|
|
|
|||
|
|
#### Modbus Validation:
|
|||
|
|
- Register addresses: 0-65535
|
|||
|
|
- Address ranges must not overlap
|
|||
|
|
- Data type compatibility with register type
|
|||
|
|
- Valid byte/word order combinations
|
|||
|
|
|
|||
|
|
#### OPC UA Validation:
|
|||
|
|
- Valid Node ID format
|
|||
|
|
- Namespace exists and accessible
|
|||
|
|
- Data type compatibility
|
|||
|
|
- Access level permissions
|
|||
|
|
|
|||
|
|
### Cross-Protocol Validation
|
|||
|
|
- Database source must exist and be accessible
|
|||
|
|
- Transformation rules must be valid
|
|||
|
|
- No duplicate mappings for same data point
|
|||
|
|
|
|||
|
|
## 📊 Performance Considerations
|
|||
|
|
|
|||
|
|
### Protocol-Specific Optimizations
|
|||
|
|
- **Modbus**: Batch register writes for efficiency
|
|||
|
|
- **OPC UA**: Use subscription model for frequent updates
|
|||
|
|
- **All**: Cache transformed values and mapping configurations
|
|||
|
|
|
|||
|
|
## 🔒 Security Considerations
|
|||
|
|
|
|||
|
|
### Protocol Security
|
|||
|
|
- **Modbus**: Validate register access permissions
|
|||
|
|
- **OPC UA**: Certificate-based authentication
|
|||
|
|
- **All**: Role-based access to mapping configuration
|
|||
|
|
|
|||
|
|
## 🚀 Implementation Phases
|
|||
|
|
|
|||
|
|
### Phase 1: Core Protocol Mapping
|
|||
|
|
- Basic mapping configuration for all protocols
|
|||
|
|
- Protocol-specific address configuration
|
|||
|
|
- Real-time preview and validation
|
|||
|
|
- Integration with existing protocol servers
|
|||
|
|
|
|||
|
|
### Phase 2: Enhanced Features
|
|||
|
|
- Drag & drop interface
|
|||
|
|
- Protocol templates
|
|||
|
|
- Bulk operations
|
|||
|
|
- Advanced transformations
|
|||
|
|
|
|||
|
|
### Phase 3: Advanced Features
|
|||
|
|
- Protocol discovery and auto-configuration
|
|||
|
|
- Mobile responsiveness
|
|||
|
|
- Performance optimizations
|
|||
|
|
- Advanced security features
|
|||
|
|
|
|||
|
|
## 📝 Testing Strategy
|
|||
|
|
|
|||
|
|
### Protocol-Specific Testing
|
|||
|
|
- **Modbus**: Register read/write operations, address validation
|
|||
|
|
- **OPC UA**: Node browsing, data type conversion, security
|
|||
|
|
- **Cross-Protocol**: Data consistency, transformation accuracy
|
|||
|
|
|
|||
|
|
## 📚 Documentation
|
|||
|
|
|
|||
|
|
### Protocol-Specific Guides
|
|||
|
|
- Modbus Mapping Configuration Guide
|
|||
|
|
- OPC UA Node Configuration Guide
|
|||
|
|
- Custom Protocol Integration Guide
|
|||
|
|
|
|||
|
|
---
|
|||
|
|
|
|||
|
|
*This document provides the comprehensive design for the Protocol Mapping UI, supporting multiple industrial protocols with a unified interface.*
|