# Dashboard Configuration Guide
|
||
|
|
|
||
|
|
## Overview
|
||
|
|
|
||
|
|
This guide explains how to configure your Calejo Control Adapter entirely through the web dashboard - no manual configuration required!
|
||
|
|
|
||
|
|
## 🎯 Your Vision Achieved
|
||
|
|
|
||
|
|
**Before**: Manual configuration files, SSH access, complex setup
|
||
|
|
**After**: One-click setup → Dashboard configuration → Ready to use
|
||
|
|
|
||
|
|
## 🚀 Getting Started
|
||
|
|
|
||
|
|
### Step 1: Run One-Click Setup
|
||
|
|
|
||
|
|
```bash
|
||
|
|
# Local development
|
||
|
|
./setup-server.sh
|
||
|
|
|
||
|
|
# Remote server
|
||
|
|
./setup-server.sh -h your-server.com -u ubuntu -k ~/.ssh/id_rsa
|
||
|
|
```
|
||
|
|
|
||
|
|
### Step 2: Access Dashboard
|
||
|
|
|
||
|
|
Open your browser and navigate to:
|
||
|
|
```
|
||
|
|
http://your-server:8080/dashboard
|
||
|
|
```
|
||
|
|
|
||
|
|
## 🔧 Complete Configuration Workflow
|
||
|
|
|
||
|
|
### 1. Configure SCADA Protocols
|
||
|
|
|
||
|
|
#### OPC UA Configuration
|
||
|
|
|
||
|
|
1. Navigate to **Protocols** → **OPC UA**
|
||
|
|
2. Configure settings:
|
||
|
|
- **Endpoint**: `opc.tcp://0.0.0.0:4840` (default)
|
||
|
|
- **Security Policy**: Basic256Sha256
|
||
|
|
- **Certificate**: Auto-generated
|
||
|
|
3. Test connection
|
||
|
|
|
||
|
|
**Example Configuration**:
|
||
|
|
```json
|
||
|
|
{
|
||
|
|
"protocol_type": "opcua",
|
||
|
|
"enabled": true,
|
||
|
|
"name": "Main OPC UA Server",
|
||
|
|
"endpoint": "opc.tcp://192.168.1.100:4840",
|
||
|
|
"security_policy": "Basic256Sha256"
|
||
|
|
}
|
||
|
|
```
|
||
|
|
|
||
|
|
#### Modbus TCP Configuration
|
||
|
|
|
||
|
|
1. Navigate to **Protocols** → **Modbus TCP**
|
||
|
|
2. Configure settings:
|
||
|
|
- **Host**: `0.0.0.0` (listen on all interfaces)
|
||
|
|
- **Port**: `502` (standard Modbus port)
|
||
|
|
- **Unit ID**: `1` (device address)
|
||
|
|
3. Test connection
|
||
|
|
|
||
|
|
**Example Configuration**:
|
||
|
|
```json
|
||
|
|
{
|
||
|
|
"protocol_type": "modbus_tcp",
|
||
|
|
"enabled": true,
|
||
|
|
"name": "Primary Modbus Network",
|
||
|
|
"host": "192.168.1.200",
|
||
|
|
"port": 502,
|
||
|
|
"unit_id": 1
|
||
|
|
}
|
||
|
|
```
|
||
|
|
|
||
|
|
### 2. Auto-Discover Hardware
|
||
|
|
|
||
|
|
1. Navigate to **Hardware** → **Auto-Discovery**
|
||
|
|
2. Select protocols to scan
|
||
|
|
3. Review discovered equipment
|
||
|
|
4. Import discovered stations and pumps
|
||
|
|
|
||
|
|
**Discovery Results**:
|
||
|
|
```json
|
||
|
|
{
|
||
|
|
"success": true,
|
||
|
|
"discovered_stations": [
|
||
|
|
{
|
||
|
|
"station_id": "station_001",
|
||
|
|
"name": "Main Pump Station",
|
||
|
|
"location": "Building A",
|
||
|
|
"max_pumps": 4
|
||
|
|
}
|
||
|
|
],
|
||
|
|
"discovered_pumps": [
|
||
|
|
{
|
||
|
|
"pump_id": "pump_001",
|
||
|
|
"station_id": "station_001",
|
||
|
|
"name": "Primary Pump",
|
||
|
|
"type": "centrifugal",
|
||
|
|
"power_rating": 55.0
|
||
|
|
}
|
||
|
|
]
|
||
|
|
}
|
||
|
|
```
|
||
|
|
|
||
|
|
### 3. Configure Pump Stations
|
||
|
|
|
||
|
|
1. Navigate to **Stations** → **Add Station**
|
||
|
|
2. Enter station details:
|
||
|
|
- **Station ID**: Unique identifier
|
||
|
|
- **Name**: Descriptive name
|
||
|
|
- **Location**: Physical location
|
||
|
|
- **Capacity**: Maximum pumps and power
|
||
|
|
|
||
|
|
**Example Station Configuration**:
|
||
|
|
```json
|
||
|
|
{
|
||
|
|
"station_id": "main_station",
|
||
|
|
"name": "Main Wastewater Pump Station",
|
||
|
|
"location": "123 Industrial Park",
|
||
|
|
"max_pumps": 6,
|
||
|
|
"power_capacity": 300.0,
|
||
|
|
"flow_capacity": 1000.0
|
||
|
|
}
|
||
|
|
```
|
||
|
|
|
||
|
|
### 4. Configure Individual Pumps
|
||
|
|
|
||
|
|
1. Navigate to **Pumps** → **Add Pump**
|
||
|
|
2. Select station
|
||
|
|
3. Enter pump specifications:
|
||
|
|
- **Pump ID**: Unique identifier
|
||
|
|
- **Type**: Centrifugal, submersible, etc.
|
||
|
|
- **Power Rating**: kW
|
||
|
|
- **Speed Range**: Min/max Hz
|
||
|
|
|
||
|
|
**Example Pump Configuration**:
|
||
|
|
```json
|
||
|
|
{
|
||
|
|
"pump_id": "primary_pump",
|
||
|
|
"station_id": "main_station",
|
||
|
|
"name": "Primary Centrifugal Pump",
|
||
|
|
"type": "centrifugal",
|
||
|
|
"power_rating": 75.0,
|
||
|
|
"max_speed": 60.0,
|
||
|
|
"min_speed": 20.0,
|
||
|
|
"vfd_model": "ABB ACS880",
|
||
|
|
"manufacturer": "Grundfos"
|
||
|
|
}
|
||
|
|
```
|
||
|
|
|
||
|
|
### 5. Set Safety Limits
|
||
|
|
|
||
|
|
1. Navigate to **Safety** → **Limits**
|
||
|
|
2. Select pump
|
||
|
|
3. Configure safety parameters:
|
||
|
|
- **Speed Limits**: Min/max Hz
|
||
|
|
- **Power Limits**: Maximum kW
|
||
|
|
- **Rate of Change**: Hz per minute
|
||
|
|
|
||
|
|
**Example Safety Configuration**:
|
||
|
|
```json
|
||
|
|
{
|
||
|
|
"station_id": "main_station",
|
||
|
|
"pump_id": "primary_pump",
|
||
|
|
"hard_min_speed_hz": 20.0,
|
||
|
|
"hard_max_speed_hz": 55.0,
|
||
|
|
"hard_max_power_kw": 80.0,
|
||
|
|
"max_speed_change_hz_per_min": 25.0
|
||
|
|
}
|
||
|
|
```
|
||
|
|
|
||
|
|
### 6. Map Data Points
|
||
|
|
|
||
|
|
1. Navigate to **Data Mapping** → **Add Mapping**
|
||
|
|
2. Configure protocol-to-internal mappings:
|
||
|
|
- **Protocol**: OPC UA, Modbus, etc.
|
||
|
|
- **Data Type**: Setpoint, actual speed, status
|
||
|
|
- **Protocol Address**: Node ID, register address
|
||
|
|
|
||
|
|
**Example Data Mapping**:
|
||
|
|
```json
|
||
|
|
{
|
||
|
|
"protocol_type": "opcua",
|
||
|
|
"station_id": "main_station",
|
||
|
|
"pump_id": "primary_pump",
|
||
|
|
"data_type": "setpoint",
|
||
|
|
"protocol_address": "ns=2;s=MainStation.PrimaryPump.Setpoint"
|
||
|
|
}
|
||
|
|
```
|
||
|
|
|
||
|
|
## 🎛️ Dashboard Features
|
||
|
|
|
||
|
|
### Real-time Monitoring
|
||
|
|
|
||
|
|
- **System Status**: Application health, protocol status
|
||
|
|
- **Performance Metrics**: CPU, memory, network usage
|
||
|
|
- **Safety Status**: Current limits, violations, emergency stop
|
||
|
|
- **Protocol Activity**: Active connections, data flow
|
||
|
|
|
||
|
|
### Operations Management
|
||
|
|
|
||
|
|
- **Emergency Stop**: Activate/deactivate through dashboard
|
||
|
|
- **Setpoint Control**: Manual override with safety enforcement
|
||
|
|
- **User Management**: Add/remove users, set roles
|
||
|
|
- **Audit Logs**: View security and operational events
|
||
|
|
|
||
|
|
### Configuration Management
|
||
|
|
|
||
|
|
- **Validation**: Check configuration completeness
|
||
|
|
- **Export/Import**: Backup and restore configurations
|
||
|
|
- **Version Control**: Track configuration changes
|
||
|
|
- **Templates**: Save and reuse configuration patterns
|
||
|
|
|
||
|
|
## 🔄 Configuration Workflow Examples
|
||
|
|
|
||
|
|
### Complete SCADA Integration
|
||
|
|
|
||
|
|
```bash
|
||
|
|
# 1. Setup server
|
||
|
|
./setup-server.sh -h scada-server.company.com -u admin -k ~/.ssh/scada_key
|
||
|
|
|
||
|
|
# 2. Access dashboard
|
||
|
|
http://scada-server.company.com:8080/dashboard
|
||
|
|
|
||
|
|
# 3. Configure protocols
|
||
|
|
- OPC UA: opc.tcp://plc-network:4840
|
||
|
|
- Modbus TCP: 192.168.1.100:502
|
||
|
|
|
||
|
|
# 4. Discover hardware
|
||
|
|
- Auto-discover connected PLCs and pumps
|
||
|
|
|
||
|
|
# 5. Set safety limits
|
||
|
|
- Min speed: 20 Hz, Max speed: 50 Hz
|
||
|
|
- Max power: 75 kW
|
||
|
|
|
||
|
|
# 6. Map data points
|
||
|
|
- OPC UA nodes to internal pump controls
|
||
|
|
|
||
|
|
# 7. Validate configuration
|
||
|
|
- Check for completeness and errors
|
||
|
|
|
||
|
|
# 8. Start operations!
|
||
|
|
```
|
||
|
|
|
||
|
|
### Quick Configuration Template
|
||
|
|
|
||
|
|
```json
|
||
|
|
{
|
||
|
|
"protocols": {
|
||
|
|
"opcua": {
|
||
|
|
"enabled": true,
|
||
|
|
"endpoint": "opc.tcp://plc-network:4840"
|
||
|
|
},
|
||
|
|
"modbus_tcp": {
|
||
|
|
"enabled": true,
|
||
|
|
"host": "192.168.1.100",
|
||
|
|
"port": 502
|
||
|
|
}
|
||
|
|
},
|
||
|
|
"stations": [
|
||
|
|
{
|
||
|
|
"station_id": "main_station",
|
||
|
|
"name": "Main Pump Station"
|
||
|
|
}
|
||
|
|
],
|
||
|
|
"pumps": [
|
||
|
|
{
|
||
|
|
"pump_id": "pump_1",
|
||
|
|
"station_id": "main_station",
|
||
|
|
"name": "Primary Pump"
|
||
|
|
}
|
||
|
|
],
|
||
|
|
"safety_limits": [
|
||
|
|
{
|
||
|
|
"pump_id": "pump_1",
|
||
|
|
"hard_min_speed_hz": 20.0,
|
||
|
|
"hard_max_speed_hz": 50.0
|
||
|
|
}
|
||
|
|
]
|
||
|
|
}
|
||
|
|
```
|
||
|
|
|
||
|
|
## 🛠️ Troubleshooting
|
||
|
|
|
||
|
|
### Common Issues
|
||
|
|
|
||
|
|
1. **Protocol Connection Failed**
|
||
|
|
- Check network connectivity
|
||
|
|
- Verify protocol settings
|
||
|
|
- Test with protocol client
|
||
|
|
|
||
|
|
2. **Hardware Not Discovered**
|
||
|
|
- Ensure protocols are configured
|
||
|
|
- Check hardware connectivity
|
||
|
|
- Verify network permissions
|
||
|
|
|
||
|
|
3. **Safety Limits Not Applied**
|
||
|
|
- Validate configuration
|
||
|
|
- Check pump mappings
|
||
|
|
- Review audit logs
|
||
|
|
|
||
|
|
### Validation Checklist
|
||
|
|
|
||
|
|
- [ ] All required protocols configured
|
||
|
|
- [ ] Pump stations defined
|
||
|
|
- [ ] Individual pumps configured
|
||
|
|
- [ ] Safety limits set for each pump
|
||
|
|
- [ ] Data mappings established
|
||
|
|
- [ ] Configuration validated
|
||
|
|
- [ ] Test connections successful
|
||
|
|
|
||
|
|
## 📞 Support
|
||
|
|
|
||
|
|
- **Dashboard Help**: Click help icons throughout the interface
|
||
|
|
- **Documentation**: Full documentation in `docs/` directory
|
||
|
|
- **Community**: Join our user community for support
|
||
|
|
- **Issues**: Report problems via GitHub issues
|
||
|
|
|
||
|
|
---
|
||
|
|
|
||
|
|
*Your Calejo Control Adapter is now fully configured and ready for SCADA integration! All configuration is managed through the intuitive web dashboard - no manual file editing required.*
|