""" Protocol Clients for Dashboard Provides client utilities to query OPC UA and Modbus servers for real-time data. """ import asyncio import structlog from typing import Dict, Any, Optional, List from datetime import datetime logger = structlog.get_logger() class OPCUAClient: """OPC UA Client for querying pump data from OPC UA server.""" def __init__(self, endpoint: str = "opc.tcp://localhost:4840"): self.endpoint = endpoint self._client = None async def connect(self): """Connect to OPC UA server.""" try: from asyncua import Client self._client = Client(url=self.endpoint) await self._client.connect() logger.info("opcua_client_connected", endpoint=self.endpoint) return True except Exception as e: logger.error("failed_to_connect_opcua", endpoint=self.endpoint, error=str(e)) return False async def disconnect(self): """Disconnect from OPC UA server.""" if self._client: await self._client.disconnect() self._client = None logger.info("opcua_client_disconnected") async def read_node_value(self, node_id: str) -> Optional[Any]: """Read value from OPC UA node.""" try: if not self._client: await self.connect() node = self._client.get_node(node_id) value = await node.read_value() return value except Exception as e: logger.error("failed_to_read_opcua_node", node_id=node_id, error=str(e)) return None async def get_pump_data(self, station_id: str, pump_id: str) -> Dict[str, Any]: """Get all data for a specific pump.""" try: if not self._client: await self.connect() # Define node IDs for this pump nodes = { "setpoint": f"ns=2;s=Station_{station_id}.Pump_{pump_id}.Setpoint_Hz", "actual_speed": f"ns=2;s=Station_{station_id}.Pump_{pump_id}.ActualSpeed_Hz", "power": f"ns=2;s=Station_{station_id}.Pump_{pump_id}.Power_kW", "flow_rate": f"ns=2;s=Station_{station_id}.Pump_{pump_id}.FlowRate_m3h", "safety_status": f"ns=2;s=Station_{station_id}.Pump_{pump_id}.SafetyStatus", "timestamp": f"ns=2;s=Station_{station_id}.Pump_{pump_id}.Timestamp" } data = {} for key, node_id in nodes.items(): value = await self.read_node_value(node_id) data[key] = value return data except Exception as e: logger.error("failed_to_get_pump_data", station_id=station_id, pump_id=pump_id, error=str(e)) return {} class ModbusClient: """Modbus Client for querying register data from Modbus server.""" def __init__(self, host: str = "localhost", port: int = 502, unit_id: int = 1): self.host = host self.port = port self.unit_id = unit_id self._client = None def connect(self) -> bool: """Connect to Modbus server.""" try: from pymodbus.client import ModbusTcpClient self._client = ModbusTcpClient(self.host, port=self.port) if self._client.connect(): logger.info("modbus_client_connected", host=self.host, port=self.port) return True else: logger.error("failed_to_connect_modbus", host=self.host, port=self.port) return False except Exception as e: logger.error("failed_to_connect_modbus", host=self.host, port=self.port, error=str(e)) return False def disconnect(self): """Disconnect from Modbus server.""" if self._client: self._client.close() self._client = None logger.info("modbus_client_disconnected") def read_holding_register(self, address: int, count: int = 1) -> Optional[List[int]]: """Read holding register(s).""" try: if not self._client or not self._client.is_socket_open(): self.connect() result = self._client.read_holding_registers(address, count) if not result.isError(): return result.registers else: logger.error("failed_to_read_holding_register", address=address, error=str(result)) return None except Exception as e: logger.error("failed_to_read_holding_register", address=address, error=str(e)) return None def read_input_register(self, address: int, count: int = 1) -> Optional[List[int]]: """Read input register(s).""" try: if not self._client or not self._client.is_socket_open(): self.connect() result = self._client.read_input_registers(address, count) if not result.isError(): return result.registers else: logger.error("failed_to_read_input_register", address=address, error=str(result)) return None except Exception as e: logger.error("failed_to_read_input_register", address=address, error=str(e)) return None def get_pump_registers(self, pump_num: int) -> Dict[str, Any]: """Get all register data for a specific pump.""" try: # Calculate base register for this pump base_register = 40000 + (pump_num * 10) # Read holding registers (setpoints) setpoint = self.read_holding_register(base_register + 1, 1) # Read input registers (status values) actual_speed = self.read_input_register(base_register + 2, 1) power = self.read_input_register(base_register + 3, 1) temperature = self.read_input_register(base_register + 4, 1) return { "setpoint": setpoint[0] if setpoint else None, "actual_speed": actual_speed[0] if actual_speed else None, "power": power[0] if power else None, "temperature": temperature[0] if temperature else None } except Exception as e: logger.error("failed_to_get_pump_registers", pump_num=pump_num, error=str(e)) return {} class ProtocolDataCollector: """Main class for collecting data from all protocol servers.""" def __init__(self): self.opcua_client = OPCUAClient() self.modbus_client = ModbusClient() async def get_signal_data(self, station_id: str, pump_id: str) -> List[Dict[str, Any]]: """Get signal data for a specific pump from all protocols.""" signals = [] # Extract pump number from pump_id (e.g., "PUMP_001" -> 1) try: pump_num = int(pump_id.split('_')[1]) except (IndexError, ValueError): pump_num = 1 # Get OPC UA data opcua_data = await self.opcua_client.get_pump_data(station_id, pump_id) # Get Modbus data modbus_data = self.modbus_client.get_pump_registers(pump_num) # Create OPC UA signals if opcua_data: # Handle None values gracefully setpoint = opcua_data.get('setpoint', 0.0) or 0.0 actual_speed = opcua_data.get('actual_speed', 0.0) or 0.0 power = opcua_data.get('power', 0.0) or 0.0 flow_rate = opcua_data.get('flow_rate', 0.0) or 0.0 safety_status = opcua_data.get('safety_status', 'normal') or 'normal' signals.extend([ { "name": f"Station_{station_id}_Pump_{pump_id}_Setpoint", "protocol": "opcua", "address": f"ns=2;s=Station_{station_id}.Pump_{pump_id}.Setpoint_Hz", "data_type": "Float", "current_value": f"{setpoint:.1f} Hz", "quality": "Good", "timestamp": datetime.now().strftime("%Y-%m-%d %H:%M:%S") }, { "name": f"Station_{station_id}_Pump_{pump_id}_ActualSpeed", "protocol": "opcua", "address": f"ns=2;s=Station_{station_id}.Pump_{pump_id}.ActualSpeed_Hz", "data_type": "Float", "current_value": f"{actual_speed:.1f} Hz", "quality": "Good", "timestamp": datetime.now().strftime("%Y-%m-%d %H:%M:%S") }, { "name": f"Station_{station_id}_Pump_{pump_id}_Power", "protocol": "opcua", "address": f"ns=2;s=Station_{station_id}.Pump_{pump_id}.Power_kW", "data_type": "Float", "current_value": f"{power:.1f} kW", "quality": "Good", "timestamp": datetime.now().strftime("%Y-%m-%d %H:%M:%S") }, { "name": f"Station_{station_id}_Pump_{pump_id}_FlowRate", "protocol": "opcua", "address": f"ns=2;s=Station_{station_id}.Pump_{pump_id}.FlowRate_m3h", "data_type": "Float", "current_value": f"{flow_rate:.1f} m³/h", "quality": "Good", "timestamp": datetime.now().strftime("%Y-%m-%d %H:%M:%S") }, { "name": f"Station_{station_id}_Pump_{pump_id}_SafetyStatus", "protocol": "opcua", "address": f"ns=2;s=Station_{station_id}.Pump_{pump_id}.SafetyStatus", "data_type": "String", "current_value": safety_status, "quality": "Good", "timestamp": datetime.now().strftime("%Y-%m-%d %H:%M:%S") } ]) # Create Modbus signals if modbus_data: # Handle None values gracefully setpoint = modbus_data.get('setpoint', 0) or 0 actual_speed = modbus_data.get('actual_speed', 0) or 0 power = modbus_data.get('power', 0) or 0 temperature = modbus_data.get('temperature', 0) or 0 signals.extend([ { "name": f"Station_{station_id}_Pump_{pump_id}_Setpoint", "protocol": "modbus", "address": f"{40000 + (pump_num * 10) + 1}", "data_type": "Integer", "current_value": f"{setpoint} Hz (x10)", "quality": "Good", "timestamp": datetime.now().strftime("%Y-%m-%d %H:%M:%S") }, { "name": f"Station_{station_id}_Pump_{pump_id}_ActualSpeed", "protocol": "modbus", "address": f"{40000 + (pump_num * 10) + 2}", "data_type": "Integer", "current_value": f"{actual_speed} Hz (x10)", "quality": "Good", "timestamp": datetime.now().strftime("%Y-%m-%d %H:%M:%S") }, { "name": f"Station_{station_id}_Pump_{pump_id}_Power", "protocol": "modbus", "address": f"{40000 + (pump_num * 10) + 3}", "data_type": "Integer", "current_value": f"{power} kW (x10)", "quality": "Good", "timestamp": datetime.now().strftime("%Y-%m-%d %H:%M:%S") }, { "name": f"Station_{station_id}_Pump_{pump_id}_Temperature", "protocol": "modbus", "address": f"{40000 + (pump_num * 10) + 4}", "data_type": "Integer", "current_value": f"{temperature} °C", "quality": "Good", "timestamp": datetime.now().strftime("%Y-%m-%d %H:%M:%S") } ]) return signals async def cleanup(self): """Clean up connections.""" await self.opcua_client.disconnect() self.modbus_client.disconnect()