{ "dashboard": { "id": null, "title": "Calejo Control Adapter - System Overview", "tags": ["calejo", "control", "scada", "monitoring"], "timezone": "browser", "panels": [ { "id": 1, "title": "System Health", "type": "stat", "targets": [ { "expr": "up{job=\"calejo-control\"}", "legendFormat": "{{instance}} - {{job}}", "refId": "A" } ], "gridPos": { "h": 8, "w": 12, "x": 0, "y": 0 }, "fieldConfig": { "defaults": { "color": { "mode": "thresholds" }, "mappings": [], "thresholds": { "steps": [ { "color": "red", "value": null }, { "color": "green", "value": 1 } ] } } } }, { "id": 2, "title": "API Response Time", "type": "timeseries", "targets": [ { "expr": "rate(http_request_duration_seconds_sum{job=\"calejo-control\"}[5m]) / rate(http_request_duration_seconds_count{job=\"calejo-control\"}[5m])", "legendFormat": "Avg Response Time", "refId": "A" } ], "gridPos": { "h": 8, "w": 12, "x": 12, "y": 0 } }, { "id": 3, "title": "HTTP Requests", "type": "timeseries", "targets": [ { "expr": "rate(http_requests_total{job=\"calejo-control\"}[5m])", "legendFormat": "{{method}} {{status}}", "refId": "A" } ], "gridPos": { "h": 8, "w": 12, "x": 0, "y": 8 } }, { "id": 4, "title": "Error Rate", "type": "timeseries", "targets": [ { "expr": "rate(http_requests_total{job=\"calejo-control\", status=~\"5..\"}[5m])", "legendFormat": "5xx Errors", "refId": "A" }, { "expr": "rate(http_requests_total{job=\"calejo-control\", status=~\"4..\"}[5m])", "legendFormat": "4xx Errors", "refId": "B" } ], "gridPos": { "h": 8, "w": 12, "x": 12, "y": 8 } }, { "id": 5, "title": "Active Connections", "type": "stat", "targets": [ { "expr": "scada_connections_active{job=\"calejo-control\"}", "legendFormat": "Active Connections", "refId": "A" } ], "gridPos": { "h": 8, "w": 8, "x": 0, "y": 16 } }, { "id": 6, "title": "Modbus Devices", "type": "stat", "targets": [ { "expr": "scada_modbus_devices_total{job=\"calejo-control\"}", "legendFormat": "Modbus Devices", "refId": "A" } ], "gridPos": { "h": 8, "w": 8, "x": 8, "y": 16 } }, { "id": 7, "title": "OPC UA Connections", "type": "stat", "targets": [ { "expr": "scada_opcua_connections_active{job=\"calejo-control\"}", "legendFormat": "OPC UA Connections", "refId": "A" } ], "gridPos": { "h": 8, "w": 8, "x": 16, "y": 16 } } ], "time": { "from": "now-1h", "to": "now" }, "timepicker": {}, "templating": { "list": [] }, "refresh": "5s", "schemaVersion": 35, "version": 0, "uid": "calejo-control-overview" }, "folderUid": "", "message": "Calejo Control Adapter Dashboard", "overwrite": true }