#!/usr/bin/env python3
|
|
"""
|
|
Mock SCADA Server for Testing
|
|
Simulates a real SCADA system with OPC UA and Modbus interfaces
|
|
"""
|
|
|
|
import asyncio
|
|
import logging
|
|
import random
|
|
import time
|
|
from datetime import datetime
|
|
from typing import Dict, Any
|
|
|
|
# OPC UA imports
|
|
try:
|
|
from asyncua import Server, Node
|
|
OPCUA_AVAILABLE = True
|
|
except ImportError:
|
|
OPCUA_AVAILABLE = False
|
|
print("Warning: asyncua not available. Install with: pip install asyncua")
|
|
|
|
# Modbus imports
|
|
try:
|
|
from pymodbus.server import StartTcpServer
|
|
from pymodbus.datastore import ModbusSequentialDataBlock
|
|
from pymodbus.datastore import ModbusSlaveContext, ModbusServerContext
|
|
MODBUS_AVAILABLE = True
|
|
except ImportError:
|
|
MODBUS_AVAILABLE = False
|
|
print("Warning: pymodbus not available. Install with: pip install pymodbus")
|
|
|
|
logging.basicConfig(level=logging.INFO)
|
|
logger = logging.getLogger(__name__)
|
|
|
|
|
|
class MockSCADAServer:
|
|
"""Mock SCADA server that simulates industrial control systems"""
|
|
|
|
def __init__(self):
|
|
self.opcua_server = None
|
|
self.modbus_server = None
|
|
self.running = False
|
|
|
|
# Simulated process data
|
|
self.process_data = {
|
|
'temperature': 25.0,
|
|
'pressure': 101.3,
|
|
'flow_rate': 100.0,
|
|
'level': 50.0,
|
|
'valve_position': 75.0,
|
|
'pump_status': True,
|
|
'alarm_status': False,
|
|
'setpoint': 100.0
|
|
}
|
|
|
|
# Historical data for trends
|
|
self.historical_data = {
|
|
'temperature': [],
|
|
'pressure': [],
|
|
'flow_rate': []
|
|
}
|
|
|
|
async def start_opcua_server(self, endpoint: str = "opc.tcp://0.0.0.0:4840"):
|
|
"""Start OPC UA server"""
|
|
if not OPCUA_AVAILABLE:
|
|
logger.warning("OPC UA not available, skipping OPC UA server")
|
|
return
|
|
|
|
try:
|
|
self.opcua_server = Server()
|
|
await self.opcua_server.init()
|
|
|
|
self.opcua_server.set_endpoint(endpoint)
|
|
self.opcua_server.set_server_name("Mock SCADA Server")
|
|
|
|
# Setup namespace
|
|
uri = "http://mock-scada.org"
|
|
idx = await self.opcua_server.register_namespace(uri)
|
|
|
|
# Create object node
|
|
objects = self.opcua_server.get_objects_node()
|
|
scada_object = await objects.add_object(idx, "SCADA_System")
|
|
|
|
# Add process variables
|
|
self.opcua_nodes = {}
|
|
for name, value in self.process_data.items():
|
|
if isinstance(value, bool):
|
|
node = await scada_object.add_variable(idx, name, value)
|
|
elif isinstance(value, (int, float)):
|
|
node = await scada_object.add_variable(idx, name, float(value))
|
|
else:
|
|
continue
|
|
await node.set_writable()
|
|
self.opcua_nodes[name] = node
|
|
|
|
await self.opcua_server.start()
|
|
logger.info(f"Mock OPC UA server started at {endpoint}")
|
|
|
|
except Exception as e:
|
|
logger.error(f"Failed to start OPC UA server: {e}")
|
|
|
|
def start_modbus_server(self, port: int = 502):
|
|
"""Start Modbus TCP server"""
|
|
if not MODBUS_AVAILABLE:
|
|
logger.warning("Modbus not available, skipping Modbus server")
|
|
return
|
|
|
|
try:
|
|
# Create data blocks
|
|
store = ModbusSlaveContext(
|
|
di=ModbusSequentialDataBlock(0, [0]*100), # Discrete Inputs
|
|
co=ModbusSequentialDataBlock(0, [0]*100), # Coils
|
|
hr=ModbusSequentialDataBlock(0, [0]*100), # Holding Registers
|
|
ir=ModbusSequentialDataBlock(0, [0]*100) # Input Registers
|
|
)
|
|
|
|
context = ModbusServerContext(slaves=store, single=True)
|
|
|
|
# Start server in background thread
|
|
import threading
|
|
def run_modbus_server():
|
|
StartTcpServer(context=context, address=("0.0.0.0", port))
|
|
|
|
modbus_thread = threading.Thread(target=run_modbus_server, daemon=True)
|
|
modbus_thread.start()
|
|
|
|
self.modbus_server = modbus_thread
|
|
logger.info(f"Mock Modbus server started on port {port}")
|
|
|
|
except Exception as e:
|
|
logger.error(f"Failed to start Modbus server: {e}")
|
|
|
|
async def update_process_data(self):
|
|
"""Update simulated process data"""
|
|
while self.running:
|
|
try:
|
|
# Simulate realistic process variations
|
|
self.process_data['temperature'] += random.uniform(-0.5, 0.5)
|
|
self.process_data['temperature'] = max(20.0, min(80.0, self.process_data['temperature']))
|
|
|
|
self.process_data['pressure'] += random.uniform(-0.1, 0.1)
|
|
self.process_data['pressure'] = max(95.0, min(110.0, self.process_data['pressure']))
|
|
|
|
self.process_data['flow_rate'] += random.uniform(-2.0, 2.0)
|
|
self.process_data['flow_rate'] = max(0.0, min(200.0, self.process_data['flow_rate']))
|
|
|
|
self.process_data['level'] += random.uniform(-1.0, 1.0)
|
|
self.process_data['level'] = max(0.0, min(100.0, self.process_data['level']))
|
|
|
|
# Simulate valve and pump behavior
|
|
if self.process_data['flow_rate'] > 150:
|
|
self.process_data['valve_position'] = max(0, self.process_data['valve_position'] - 1)
|
|
elif self.process_data['flow_rate'] < 50:
|
|
self.process_data['valve_position'] = min(100, self.process_data['valve_position'] + 1)
|
|
|
|
# Simulate alarms
|
|
self.process_data['alarm_status'] = (
|
|
self.process_data['temperature'] > 75.0 or
|
|
self.process_data['pressure'] > 108.0 or
|
|
self.process_data['level'] > 95.0
|
|
)
|
|
|
|
# Update OPC UA nodes if available
|
|
if self.opcua_server and self.opcua_nodes:
|
|
for name, node in self.opcua_nodes.items():
|
|
await node.write_value(self.process_data[name])
|
|
|
|
# Store historical data
|
|
timestamp = datetime.now()
|
|
self.historical_data['temperature'].append({
|
|
'timestamp': timestamp,
|
|
'value': self.process_data['temperature']
|
|
})
|
|
self.historical_data['pressure'].append({
|
|
'timestamp': timestamp,
|
|
'value': self.process_data['pressure']
|
|
})
|
|
self.historical_data['flow_rate'].append({
|
|
'timestamp': timestamp,
|
|
'value': self.process_data['flow_rate']
|
|
})
|
|
|
|
# Keep only last 1000 points
|
|
for key in self.historical_data:
|
|
if len(self.historical_data[key]) > 1000:
|
|
self.historical_data[key] = self.historical_data[key][-1000:]
|
|
|
|
await asyncio.sleep(1) # Update every second
|
|
|
|
except Exception as e:
|
|
logger.error(f"Error updating process data: {e}")
|
|
await asyncio.sleep(5)
|
|
|
|
def get_status(self) -> Dict[str, Any]:
|
|
"""Get server status"""
|
|
return {
|
|
'running': self.running,
|
|
'opcua_available': OPCUA_AVAILABLE and self.opcua_server is not None,
|
|
'modbus_available': MODBUS_AVAILABLE and self.modbus_server is not None,
|
|
'process_data': self.process_data,
|
|
'data_points': sum(len(data) for data in self.historical_data.values())
|
|
}
|
|
|
|
async def start(self):
|
|
"""Start the mock SCADA server"""
|
|
if self.running:
|
|
return
|
|
|
|
self.running = True
|
|
|
|
# Start servers
|
|
await self.start_opcua_server()
|
|
self.start_modbus_server()
|
|
|
|
# Start data update loop
|
|
self.update_task = asyncio.create_task(self.update_process_data())
|
|
|
|
logger.info("Mock SCADA server started")
|
|
|
|
async def stop(self):
|
|
"""Stop the mock SCADA server"""
|
|
self.running = False
|
|
|
|
if hasattr(self, 'update_task'):
|
|
self.update_task.cancel()
|
|
try:
|
|
await self.update_task
|
|
except asyncio.CancelledError:
|
|
pass
|
|
|
|
if self.opcua_server:
|
|
await self.opcua_server.stop()
|
|
|
|
logger.info("Mock SCADA server stopped")
|
|
|
|
|
|
async def main():
|
|
"""Main function to run the mock SCADA server"""
|
|
server = MockSCADAServer()
|
|
|
|
try:
|
|
await server.start()
|
|
|
|
# Keep server running
|
|
while True:
|
|
await asyncio.sleep(1)
|
|
|
|
except KeyboardInterrupt:
|
|
print("\nShutting down mock SCADA server...")
|
|
await server.stop()
|
|
|
|
|
|
if __name__ == "__main__":
|
|
asyncio.run(main()) |