7.2 KiB
7.2 KiB
Dashboard Configuration Guide
Overview
This guide explains how to configure your Calejo Control Adapter entirely through the web dashboard - no manual configuration required!
🎯 Your Vision Achieved
Before: Manual configuration files, SSH access, complex setup After: One-click setup → Dashboard configuration → Ready to use
🚀 Getting Started
Step 1: Run One-Click Setup
# Local development
./setup-server.sh
# Remote server
./setup-server.sh -h your-server.com -u ubuntu -k ~/.ssh/id_rsa
Step 2: Access Dashboard
Open your browser and navigate to:
http://your-server:8080/dashboard
🔧 Complete Configuration Workflow
1. Configure SCADA Protocols
OPC UA Configuration
- Navigate to Protocols → OPC UA
- Configure settings:
- Endpoint:
opc.tcp://0.0.0.0:4840(default) - Security Policy: Basic256Sha256
- Certificate: Auto-generated
- Endpoint:
- Test connection
Example Configuration:
{
"protocol_type": "opcua",
"enabled": true,
"name": "Main OPC UA Server",
"endpoint": "opc.tcp://192.168.1.100:4840",
"security_policy": "Basic256Sha256"
}
Modbus TCP Configuration
- Navigate to Protocols → Modbus TCP
- Configure settings:
- Host:
0.0.0.0(listen on all interfaces) - Port:
502(standard Modbus port) - Unit ID:
1(device address)
- Host:
- Test connection
Example Configuration:
{
"protocol_type": "modbus_tcp",
"enabled": true,
"name": "Primary Modbus Network",
"host": "192.168.1.200",
"port": 502,
"unit_id": 1
}
2. Auto-Discover Hardware
- Navigate to Hardware → Auto-Discovery
- Select protocols to scan
- Review discovered equipment
- Import discovered stations and pumps
Discovery Results:
{
"success": true,
"discovered_stations": [
{
"station_id": "station_001",
"name": "Main Pump Station",
"location": "Building A",
"max_pumps": 4
}
],
"discovered_pumps": [
{
"pump_id": "pump_001",
"station_id": "station_001",
"name": "Primary Pump",
"type": "centrifugal",
"power_rating": 55.0
}
]
}
3. Configure Pump Stations
- Navigate to Stations → Add Station
- Enter station details:
- Station ID: Unique identifier
- Name: Descriptive name
- Location: Physical location
- Capacity: Maximum pumps and power
Example Station Configuration:
{
"station_id": "main_station",
"name": "Main Wastewater Pump Station",
"location": "123 Industrial Park",
"max_pumps": 6,
"power_capacity": 300.0,
"flow_capacity": 1000.0
}
4. Configure Individual Pumps
- Navigate to Pumps → Add Pump
- Select station
- Enter pump specifications:
- Pump ID: Unique identifier
- Type: Centrifugal, submersible, etc.
- Power Rating: kW
- Speed Range: Min/max Hz
Example Pump Configuration:
{
"pump_id": "primary_pump",
"station_id": "main_station",
"name": "Primary Centrifugal Pump",
"type": "centrifugal",
"power_rating": 75.0,
"max_speed": 60.0,
"min_speed": 20.0,
"vfd_model": "ABB ACS880",
"manufacturer": "Grundfos"
}
5. Set Safety Limits
- Navigate to Safety → Limits
- Select pump
- Configure safety parameters:
- Speed Limits: Min/max Hz
- Power Limits: Maximum kW
- Rate of Change: Hz per minute
Example Safety Configuration:
{
"station_id": "main_station",
"pump_id": "primary_pump",
"hard_min_speed_hz": 20.0,
"hard_max_speed_hz": 55.0,
"hard_max_power_kw": 80.0,
"max_speed_change_hz_per_min": 25.0
}
6. Map Data Points
- Navigate to Data Mapping → Add Mapping
- Configure protocol-to-internal mappings:
- Protocol: OPC UA, Modbus, etc.
- Data Type: Setpoint, actual speed, status
- Protocol Address: Node ID, register address
Example Data Mapping:
{
"protocol_type": "opcua",
"station_id": "main_station",
"pump_id": "primary_pump",
"data_type": "setpoint",
"protocol_address": "ns=2;s=MainStation.PrimaryPump.Setpoint"
}
🎛️ Dashboard Features
Real-time Monitoring
- System Status: Application health, protocol status
- Performance Metrics: CPU, memory, network usage
- Safety Status: Current limits, violations, emergency stop
- Protocol Activity: Active connections, data flow
Operations Management
- Emergency Stop: Activate/deactivate through dashboard
- Setpoint Control: Manual override with safety enforcement
- User Management: Add/remove users, set roles
- Audit Logs: View security and operational events
Configuration Management
- Validation: Check configuration completeness
- Export/Import: Backup and restore configurations
- Version Control: Track configuration changes
- Templates: Save and reuse configuration patterns
🔄 Configuration Workflow Examples
Complete SCADA Integration
# 1. Setup server
./setup-server.sh -h scada-server.company.com -u admin -k ~/.ssh/scada_key
# 2. Access dashboard
http://scada-server.company.com:8080/dashboard
# 3. Configure protocols
- OPC UA: opc.tcp://plc-network:4840
- Modbus TCP: 192.168.1.100:502
# 4. Discover hardware
- Auto-discover connected PLCs and pumps
# 5. Set safety limits
- Min speed: 20 Hz, Max speed: 50 Hz
- Max power: 75 kW
# 6. Map data points
- OPC UA nodes to internal pump controls
# 7. Validate configuration
- Check for completeness and errors
# 8. Start operations!
Quick Configuration Template
{
"protocols": {
"opcua": {
"enabled": true,
"endpoint": "opc.tcp://plc-network:4840"
},
"modbus_tcp": {
"enabled": true,
"host": "192.168.1.100",
"port": 502
}
},
"stations": [
{
"station_id": "main_station",
"name": "Main Pump Station"
}
],
"pumps": [
{
"pump_id": "pump_1",
"station_id": "main_station",
"name": "Primary Pump"
}
],
"safety_limits": [
{
"pump_id": "pump_1",
"hard_min_speed_hz": 20.0,
"hard_max_speed_hz": 50.0
}
]
}
🛠️ Troubleshooting
Common Issues
-
Protocol Connection Failed
- Check network connectivity
- Verify protocol settings
- Test with protocol client
-
Hardware Not Discovered
- Ensure protocols are configured
- Check hardware connectivity
- Verify network permissions
-
Safety Limits Not Applied
- Validate configuration
- Check pump mappings
- Review audit logs
Validation Checklist
- All required protocols configured
- Pump stations defined
- Individual pumps configured
- Safety limits set for each pump
- Data mappings established
- Configuration validated
- Test connections successful
📞 Support
- Dashboard Help: Click help icons throughout the interface
- Documentation: Full documentation in
docs/directory - Community: Join our user community for support
- Issues: Report problems via GitHub issues
Your Calejo Control Adapter is now fully configured and ready for SCADA integration! All configuration is managed through the intuitive web dashboard - no manual file editing required.