# Protocol Mapping Configuration UI Design
## Overview
This document outlines the comprehensive UI design for configuring database-to-protocol mappings through the dashboard interface, supporting Modbus, OPC UA, and other industrial protocols.
## 🎯 Design Goals
- **Intuitive**: Easy for both technical and non-technical users
- **Visual**: Clear representation of database-to-protocol data flow
- **Configurable**: Flexible mapping configuration without code changes
- **Validated**: Real-time conflict detection and validation
- **Scalable**: Support for multiple stations, pumps, and protocols
- **Protocol-Agnostic**: Unified interface for Modbus, OPC UA, and other protocols
## 🏗️ Architecture
### Data Flow
```
Database Sources → Mapping Configuration → Protocol Endpoints
↓ ↓ ↓
pump_plans.speed_hz → Setpoint mapping → Modbus: Holding register 40001
pumps.status_code → Status mapping → OPC UA: ns=2;s=Station.Pump.Status
safety.flags → Safety mapping → Modbus: Coil register 0
flow_meters.rate → Flow mapping → OPC UA: ns=2;s=Station.Flow.Rate
```
### Component Structure
```javascript
<ProtocolMappingDashboard>
<ProtocolSelector />
<StationSelector />
<PumpSelector />
<MappingGrid />
<MappingConfigurationModal />
<RealTimePreview />
<ValidationPanel />
<TemplateGallery />
<BulkOperations />
</ProtocolMappingDashboard>
```
## 📋 UI Components
### 1. Main Dashboard Layout
```
┌─────────────────────────────────────────────────────────────────┐
│ PROTOCOL MAPPING CONFIGURATION │
├─────────────────────────────────────────────────────────────────┤
│ [Protocols] [Stations] [Pumps] [Mapping View] [Templates] │
└─────────────────────────────────────────────────────────────────┘
```
### 2. Visual Protocol Mapping View
#### **Layout**:
```
┌─────────────────┐ ┌─────────────────────────────────────────────┐
│ │ │ PROTOCOL MAPPING │
│ PUMP LIST │ │ ┌───┬─────────────┬─────────────┬─────────┐ │
│ │ │ │ # │ DATA TYPE │ DB SOURCE │ ADDRESS │ │
│ STATION_001 │ │ ├───┼─────────────┼─────────────┼─────────┤ │
│ ├─ PUMP_001 │ │ │ 0 │ Setpoint │ speed_hz │ 40001 │ │
│ ├─ PUMP_002 │ │ │ 1 │ Status │ status_code │ 40002 │ │
│ ├─ PUMP_003 │ │ │ 2 │ Power │ power_kw │ 40003 │ │
│ │ │ │ 3 │ Level │ level_m │ 40004 │ │
│ STATION_002 │ │ │ 4 │ Flow │ flow_m3h │ 40005 │ │
│ ├─ PUMP_004 │ │ │ 5 │ Safety │ safety_flag │ 40006 │ │
│ │ │ └───┴─────────────┴─────────────┴─────────┘ │
└─────────────────┘ └─────────────────────────────────────────────┘
```
### 3. Multi-Protocol Configuration Form
#### **Modal/Form Layout**:
```
┌─────────────────────────────────────────────────────────────────┐
│ CONFIGURE PROTOCOL MAPPING │
├─────────────────────────────────────────────────────────────────┤
│ Protocol: [Modbus TCP ▼] [OPC UA ▼] [Custom Protocol] │
│ │
│ Station: [STATION_001 ▼] Pump: [PUMP_001 ▼] │
│ │
│ Data Type: [Setpoint ▼] Protocol Address: │
│ │
│ MODBUS: [40001] (Holding Register) │
│ OPC UA: [ns=2;s=Station.Pump.Setpoint] │
│ │
│ Database Source: │
│ [●] pump_plans.suggested_speed_hz │
│ [ ] pumps.default_setpoint_hz │
│ [ ] Custom SQL: [___________________________] │
│ │
│ Data Transformation: │
│ [●] Direct value [ ] Scale: [×10] [÷10] │
│ [ ] Offset: [+___] [ ] Clamp: [min___] [max___] │
│ │
│ Validation: ✅ No conflicts detected │
│ │
│ [SAVE MAPPING] [TEST MAPPING] [CANCEL] │
└─────────────────────────────────────────────────────────────────┘
```
### 4. Protocol-Specific Address Configuration
#### **Modbus Configuration**:
```
┌─────────────────────────────────────────────────────────────────┐
│ MODBUS ADDRESS CONFIGURATION │
├─────────────────────────────────────────────────────────────────┤
│ Register Type: [● Holding ○ Input ○ Coil ○ Discrete] │
│ │
│ Address: [40001] │
│ Size: [1 register] │
│ Data Type: [16-bit integer] │
│ │
│ Byte Order: [Big Endian] [Little Endian] │
│ Word Order: [High Word First] [Low Word First] │
└─────────────────────────────────────────────────────────────────┘
```
#### **OPC UA Configuration**:
```
┌─────────────────────────────────────────────────────────────────┐
│ OPC UA NODE CONFIGURATION │
├─────────────────────────────────────────────────────────────────┤
│ Node ID: [ns=2;s=Station.Pump.Setpoint] │
│ │
│ Namespace: [2] │
│ Browse Name: [Setpoint] │
│ Display Name: [Pump Setpoint] │
│ │
│ Data Type: [Double] [Float] [Int32] [Int16] [Boolean] │
│ Access Level: [CurrentRead] [CurrentWrite] [HistoryRead] │
└─────────────────────────────────────────────────────────────────┘
```
### 5. Drag & Drop Interface
#### **Visual Design**:
```
┌─────────────────┐ ┌─────────────────┐ ┌─────────────────┐
│ DATABASE │ │ MAPPING │ │ PROTOCOL │
│ SOURCES │ │ WORKSPACE │ │ ENDPOINTS │
│ │ │ │ │ │
│ ┌─────────────┐ │ │ ┌─────────────┐ │ │ ┌─────────────┐ │
│ │ pump_plans │ │ │ │ Setpoint │ │ │ │ Modbus │ │
│ │ speed_hz │──────▶│ speed_hz │──────▶│ 40001 │ │
│ └─────────────┘ │ │ └─────────────┘ │ │ └─────────────┘ │
│ │ │ │ │ │
│ ┌─────────────┐ │ │ ┌─────────────┐ │ │ ┌─────────────┐ │
│ │ pumps │ │ │ │ Status │ │ │ │ OPC UA │ │
│ │ status │──────▶│ status_code │──────▶│ ns=2;s=... │ │
│ └─────────────┘ │ │ └─────────────┘ │ │ └─────────────┘ │
│ │ │ │ │ │
│ ┌─────────────┐ │ │ ┌─────────────┐ │ │ ┌─────────────┐ │
│ │ safety │ │ │ │ Safety │ │ │ │ Modbus │ │
│ │ flags │──────▶│ safety_flag │──────▶│ Coil 0 │ │
│ └─────────────┘ │ │ └─────────────┘ │ │ └─────────────┘ │
└─────────────────┘ └─────────────────┘ └─────────────────┘
```
### 6. Real-time Preview Panel
#### **Layout**:
```
┌─────────────────────────────────────────────────────────────────┐
│ REAL-TIME PREVIEW │
├─────────────────┬─────────────┬─────────────┬───────────────────┤
│ Database Value │ Transform │ Protocol │ Current Value │
├─────────────────┼─────────────┼─────────────┼───────────────────┤
│ 42.3 Hz │ ×10 → │ Modbus 40001│ 423 │
│ Running │ Direct │ OPC UA Node │ 1 │
│ 15.2 kW │ Direct │ Modbus 40003│ 15 │
│ 2.1 m │ ×100 → │ OPC UA Node │ 210 │
└─────────────────┴─────────────┴─────────────┴───────────────────┘
```
### 7. Protocol-Specific Templates
#### **Template Gallery**:
```
┌─────────────────────────────────────────────────────────────────┐
│ PROTOCOL TEMPLATES │
├─────────────────┬─────────────────┬─────────────────────────────┤
│ Modbus Standard │ OPC UA Standard │ Custom Template │
│ │ │ │
│ • Holding Regs │ • Analog Items │ • Import from file │
│ • Input Regs │ • Digital Items │ • Export current │
│ • Coils │ • Complex Types │ • Save as template │
│ • Discrete │ • Methods │ │
│ │ │ │
│ [APPLY] │ [APPLY] │ [CREATE] │
└─────────────────┴─────────────────┴─────────────────────────────┘
```
## 🔧 Technical Implementation
### Data Models
```typescript
interface ProtocolMapping {
id: string;
protocolType: 'modbus_tcp' | 'opcua' | 'custom';
stationId: string;
pumpId: string;
dataType: 'setpoint' | 'status' | 'power' | 'flow' | 'level' | 'safety';
protocolAddress: string; // Register address or OPC UA node
dbSource: string;
transformation: TransformationRule[];
// Protocol-specific properties
modbusConfig?: {
registerType: 'holding' | 'input' | 'coil' | 'discrete';
size: number;
dataType: 'int16' | 'int32' | 'float' | 'boolean';
byteOrder: 'big_endian' | 'little_endian';
};
opcuaConfig?: {
namespace: number;
browseName: string;
displayName: string;
dataType: string;
accessLevel: string[];
};
}
interface TransformationRule {
type: 'scale' | 'offset' | 'clamp' | 'round';
parameters: any;
}
```
### API Endpoints
```
GET /api/v1/dashboard/protocol-mappings
POST /api/v1/dashboard/protocol-mappings
PUT /api/v1/dashboard/protocol-mappings/{id}
DELETE /api/v1/dashboard/protocol-mappings/{id}
POST /api/v1/dashboard/protocol-mappings/validate
POST /api/v1/dashboard/protocol-mappings/test
GET /api/v1/dashboard/protocol-mappings/templates
POST /api/v1/dashboard/protocol-mappings/import
GET /api/v1/dashboard/protocol-mappings/export
# Protocol-specific endpoints
GET /api/v1/dashboard/protocol-mappings/modbus
GET /api/v1/dashboard/protocol-mappings/opcua
POST /api/v1/dashboard/protocol-mappings/modbus/discover
POST /api/v1/dashboard/protocol-mappings/opcua/browse
```
### Integration Points
#### 1. Configuration Manager Integration
```python
class ConfigurationManager:
def __init__(self):
self.protocol_mappings: List[ProtocolMapping] = []
def add_protocol_mapping(self, mapping: ProtocolMapping) -> bool:
# Validate and add mapping
pass
def get_protocol_mappings(self,
protocol_type: str = None,
station_id: str = None,
pump_id: str = None) -> List[ProtocolMapping]:
# Filter mappings by protocol/station/pump
pass
```
#### 2. Protocol Server Integration
```python
# Modbus Server Integration
class ModbusServer:
def __init__(self, configuration_manager: ConfigurationManager):
self.configuration_manager = configuration_manager
async def _update_registers(self):
modbus_mappings = self.configuration_manager.get_protocol_mappings('modbus_tcp')
for mapping in modbus_mappings:
value = self._get_database_value(mapping.dbSource)
transformed_value = self._apply_transformations(value, mapping.transformation)
self._write_register(mapping.protocolAddress, transformed_value, mapping.modbusConfig.registerType)
# OPC UA Server Integration
class OPCUAServer:
def __init__(self, configuration_manager: ConfigurationManager):
self.configuration_manager = configuration_manager
async def update_nodes(self):
opcua_mappings = self.configuration_manager.get_protocol_mappings('opcua')
for mapping in opcua_mappings:
value = self._get_database_value(mapping.dbSource)
transformed_value = self._apply_transformations(value, mapping.transformation)
await self._write_node(mapping.protocolAddress, transformed_value)
```
## 🎨 Visual Design System
### Color Scheme by Protocol
- **Modbus**: Blue (#2563eb)
- **OPC UA**: Green (#16a34a)
- **Custom Protocols**: Purple (#9333ea)
- **Success**: Green (#16a34a)
- **Warning**: Yellow (#d97706)
- **Error**: Red (#dc2626)
### Icons
- 🔌 Modbus
- 🌐 OPC UA
- ⚙️ Custom Protocol
- ✅ Valid mapping
- ⚠️ Warning
- ❌ Error
- 🔄 Active/live data
- 📊 Data preview
## 🔍 Validation Rules
### Protocol-Specific Validation
#### Modbus Validation:
- Register addresses: 0-65535
- Address ranges must not overlap
- Data type compatibility with register type
- Valid byte/word order combinations
#### OPC UA Validation:
- Valid Node ID format
- Namespace exists and accessible
- Data type compatibility
- Access level permissions
### Cross-Protocol Validation
- Database source must exist and be accessible
- Transformation rules must be valid
- No duplicate mappings for same data point
## 📊 Performance Considerations
### Protocol-Specific Optimizations
- **Modbus**: Batch register writes for efficiency
- **OPC UA**: Use subscription model for frequent updates
- **All**: Cache transformed values and mapping configurations
## 🔒 Security Considerations
### Protocol Security
- **Modbus**: Validate register access permissions
- **OPC UA**: Certificate-based authentication
- **All**: Role-based access to mapping configuration
## 🚀 Implementation Phases
### Phase 1: Core Protocol Mapping
- Basic mapping configuration for all protocols
- Protocol-specific address configuration
- Real-time preview and validation
- Integration with existing protocol servers
### Phase 2: Enhanced Features
- Drag & drop interface
- Protocol templates
- Bulk operations
- Advanced transformations
### Phase 3: Advanced Features
- Protocol discovery and auto-configuration
- Mobile responsiveness
- Performance optimizations
- Advanced security features
## 📝 Testing Strategy
### Protocol-Specific Testing
- **Modbus**: Register read/write operations, address validation
- **OPC UA**: Node browsing, data type conversion, security
- **Cross-Protocol**: Data consistency, transformation accuracy
## 📚 Documentation
### Protocol-Specific Guides
- Modbus Mapping Configuration Guide
- OPC UA Node Configuration Guide
- Custom Protocol Integration Guide
---
*This document provides the comprehensive design for the Protocol Mapping UI, supporting multiple industrial protocols with a unified interface.*